TMF magnetic pump
TMF series is the latest research and development of our company’s new upgraded magnetic pump, is the main product, high efficiency and energy saving, low price, welcome to consult and buy!
TMF fluorine plastic magnetic pump, made of HT200 steel lining corrosion-resistant plastic, specializing in the transportation and transportation of all kinds of acid. It is ideal for a variety of acidic liquid projects.The products are made according to CE,ISO9001 standard and can be customized to ANSI flange standard.
Main parameters of Teflon fluoroplastic magnetic pump:
- Flow: 1.6m³/ h – 200m³/ h(1600L/h-200000L/h).
- Head: 5 m-80 m (0.5bar-8bar).
- Power: 1.5kW-55kW (2HP-75HP).
- Suitable medium: any concentration of sulfuric acid, alkali, salt, organic solvent, etc.
- Lining material: PTFE,FEP,PVDF,PP,PFA,TEFLON.
- Operating temperature:-20 ℃ to 150 ℃ medium density: 1.8 or lower.
Our company can according to the actual working conditions, choose different configurations, to provide accurate solutions.
-6-283x300.jpg)
Product photos
In stock supply, multiple models and diverse choices.

Notice reminder
1. Prevent particles from entering
(1) Do not allow ferromagnetic impurities and particles to enter the magnetic drive and bearing friction pair.
(2) After transporting the medium that is easy to crystallize or precipitate, it is necessary to rinse it in time (after stopping the pump, water is injected into the pump chamber, and it is discharged after 1min of operation) to ensure the service life of the sliding bearing.
(3) When conveying the medium containing solid particles, it should be filtered at the inlet of the pump flow pipe.
⒉ Prevent demagnetization
(1) The magnetic torque should not be designed too small. (2) It should be operated under the specified temperature conditions, and the medium temperature is strictly prohibited. A platinum resistance temperature sensor can be installed on the outer surface of the magnetic pump isolation sleeve to detect the temperature rise in the ring gap area, so as to alarm or stop when the temperature exceeds the limit.
It prevents dry friction
(1) No idling.
(2) Strictly prohibit the evacuation of the medium.
(3) When the outlet valve is closed, the continuous operation time of the pump shall not exceed 2min to prevent the magnetic drive from overheating and failing.

Troubleshooting method
| malfunction | reason | solution |
| No liquid can come out | 1. There is air in the suction tube
2. There is air leakage in the suction tube |
Reperfusion the liquid or drain the gas.
2. Check the suction pipe |
| underflow | 1. The impeller is damaged. 2. The speed is insufficient | 1.Replace the impeller.
2. Check the motor and power supply circuit |
| overpower | The conveying medium is too heavy | Reduce viscosity or increase perfusion pressure |
| underhead | 1.There is air in the conveying medium.
2. The impeller is damaged 3.Dielectric hypergravity |
1.Repour the liquid or drain the gas. 2. Replace the impeller 3.Reduce viscosity or increase perfusion pressure |
|
pump set vibration |
Pump axis and motor axis error is too large suction height, resulting in cavitation |
Adjust and lower the installation height |
|
Shaft end leakage and seal leakage |
The gap of the ring at the end of the shaft is too large, and the suction height of the ring is too high, resulting in cavitation |
Adjust the clasp screws to lower the installation height |
Structure of magnetic pump
(1) Magnetic coupler
The magnetic drive is accomplished by magnetic couplers. Magnetic coupler mainly includes internal magnetic cylinder, external magnetic cylinder and isolation sleeve and other components, is the core components of magnetic pump. The structure of magnetic coupler, magnetic circuit design and the material of each component are related to the reliability, magnetic transmission efficiency and life of magnetic pump. The magnetic coupler is suitable for outdoor starting and continuous operation under specified environmental conditions, and should not appear decoupling and demagnetization.

① Inner and outer magnetic cylinder The inner magnetic cylinder should be firmly fixed on the guide ring with adhesive, and the inner magnetic cylinder and the medium should be isolated with a jacket.
The isolation sleeve, also known as the isolation cover or sealing sleeve, is located between the inner and outer magnetic cylinders, completely separate the inner and outer magnetic cylinders, and the medium is closed in the isolation sleeve. The thickness of the isolation sleeve is related to the working pressure and the use temperature, too thick, it will increase the gap size of the inner and outer magnetic cylinder, reduce the magnetic transmission torque, and increase the eddy current loss in the isolation sleeve, thus affecting the magnetic transmission efficiency, too thin, it will affect the strength and stiffness.
There are two kinds of isolation sets, metal and non-metal, metal isolation sets have eddy current loss, non-metal isolation sets have no eddy current loss. Metal isolation sleeve should be selected with high resistivity materials, such as Hastelloy, titanium alloy, etc., can also be selected austenitic stainless steel, its thickness is generally 1.0~1.2mm. For low-power magnetic pumps, and when the use temperature is low, the isolation sleeve can also be considered using non-metallic materials, such as plastic or ceramic.
(2) plain bearings
① Silicon carbide ceramic magnetic pump generally uses silicon carbide ceramic bearings. In order to prevent silicon carbide containing free silicon, thereby reducing its corrosion resistance, it is generally required to use non-press-sintered A-phase silicon carbide. Silicon carbide bearing, high bearing capacity, and has strong erosion resistance, chemical corrosion resistance, wear resistance and good heat resistance, the use of temperature up to 500℃. The service life of silicon carbide plain bearings can generally reach more than 3 years.
Silicon carbide bearings are usually mounted on metal parts. Since the thermal expansion coefficient of silicon carbide is much smaller than that of general metal materials, special mounting structures (such as metal corrugated pads) or special metal materials (such as titanium alloy) should be used when conveying high or low temperature media.
Graphite graphite has good self-lubrication performance, can withstand a short period of dry operation, the use of temperature up to 450℃, the disadvantage is poor wear resistance. The service life of graphite plain bearings can generally reach more than 1 year.
Dimension figure
-9-300x189.jpg)
-10-300x263.jpg)
Customer praise
1. The quality is very good, completely consistent with the seller’s description, really like, completely beyond expectations, the delivery speed is very fast, the packaging is very careful and strict, the logistics company’s service attitude is very good, the delivery speed is very fast, and the quality of shopping is very good, I hope more friends trust. The attitude of the owner is very good, I will patronize the good seller again, the delivery is rapid, the attitude is very good, very satisfied! Very good, very good! Online shopping is so fierce, did not expect the service of the store is so good, the quality of goods is good and the price is low, the seller is very enthusiastic, the next time to hope that the next opportunity to cooperate I wish you a prosperous business quality is very good, the packaging is very careful beyond my expectations. The next opportunity to find you again, the store is very good, the pump is very good, to buy the heart of the baby is a very happy thing, the quality is very good, completely consistent with the seller’s description, really like, completely beyond expectations, the delivery speed is very fast, the packaging is very careful, strict, logistics company service attitude is very good, fast delivery.
2. Magnetic pump is very good, cheap and fast express! Will buy back!
3.pump received, very satisfied, really is a super good business, answer questions, meticulous and serious, there are professional technical guidance. The key is that the stuff is good, and the goods are shipped super-fast, packed carefully, and trusted.
4.At the beginning, I don’t know how to select, there are too many kinds of pumps, but also the customer service attitude is serious, technical professional, tell the parameters and working conditions immediately adapted to the right model, with half a year without any problems, great! Thank you very much for Nanjing Teflon equipment, it is really a pleasant shopping! Have been recommended to friends around, everyone said the quality is great!
5.Friends introduced the manufacturers, to the Teflon factory field visit after the rest of the purchase, Teflon factory area is very large, professional workers, they have regular technical training, testing and assessment is also very strict! After visiting their factory immediately placed an order, as expected, it has been used for nearly 2 years, no damage. The new project is about to go on, come to buy it now!
TMF series can be customized according to specific working conditions.
- 1.High temperature type-G, High temperature 180 degrees Celsius.
- 2.Lye type-J, Transportation of alkaline liquid.
- 3.Granular type-K, Transport 10% particulate matter.
For other special requirements, please contact us.