Introduction

ZFT fluorine-lined self-priming magnetic pump has the advantages of compact structure, easy operation, smooth operation, easy maintenance, high efficiency, long life, and strong self-priming ability. The pipeline does not need to install the bottom valve, and only need to ensure that there is a quantitative primer stored in the pump body before work. Different liquids can be self-priming pumps of different materials.

Operating principle

ZFT series self-priming magnetic pump, combined with the advantages of magnetic pump and self-priming pump, has a strong self-priming function, cancel the shaft seal, the use of magnetic indirect transmission, completely eliminate the phenomenon of dripping.

Range of application

Low water pool, tank truck raw material loading and unloading, gas-liquid mixed media, etc

Factory real show

 

The reason and the solution of the pump without water

The reasons and solutions of self-priming pump without water are as follows:

1. No storage liquid or insufficient storage liquid in the body of self-priming pump: add enough.

2. Suction pipeline leakage: Eliminate pipeline leakage phenomenon, check method within the allowed suction range of the pump start 4-5 minutes water has not been sucked up, please use the ear close to the inlet pipeline suspected of leaking to listen to the sound of aspiration, or in the suspected of leaking place coating white latex and other methods to repair.

3. The suction range is too high or the suction pipe is too long: reduce the suction or shorten the pipe.

4, the outlet pipeline installation is incorrect too many bends: too many pipelines into N font It is recommended to install automatic exhaust valve at the highest point.

5. The filter screen of the pump body or the inlet pipeline is blocked by debris stones: check and clean up the blockage.

6. Mechanical seal leakage is too large: repair or replace.

7, impeller damage or wear: replace the new impeller.

8, the self-priming pump return hole is blocked, resulting in soda can not be separated: check and clean up.

9, three-phase motor wiring reverse: interchange of two phases.

10. The voltage is too low: Adjust the voltage.

 

Self suction height and suction height

One: self-priming height

Refers to the vertical distance from the center of the pump impeller to the liquid surface. The determining factor is the size of the liquid storage chamber in the design process of the pump, the larger the liquid storage chamber, the more cooling water can be provided to the mechanical seal, the more the pump can withstand the empty operation during the self-priming, the longer the time of the same air rotation, the more air discharged, the higher the self-priming height. The empty running time of the general mechanical seal can not exceed 30s, but the self-priming pump can be maintained within 3 minutes. The self-priming height is generally within 3m.

Two: Suck up height

The suction height is also called the suction range of the pump or the necessary cavitation allowance △h, the calculation formula is: △h=10.33m atmospheric pressure water column – the cavitation allowance of the pump – pipeline loss. In the formula, 10.33m is the standard atmospheric pressure (sea level), and if the pressure is reduced at a high altitude, the suction height will also decrease. The cavitation margin is a data that has been formed during the design process of the pump, and is generally a given value. Pipeline loss, etc., the general value is 0.5m, which also includes the safety margin.

Installation points to emphasize:

1, the outlet pipe must be kept unobtruded, pay special attention to not install the check valve, if you have to install, please install a bypass valve between the check valve and the pump outlet for exhaust, when the exhaust valve water, closed can work normally.

2, the parallel pipeline distance of the pump shall not exceed 0.5 meters, otherwise it will also affect the self-priming height, because the air in the parallel pipeline is also required to discharge the self-priming pump.

3, the pump inlet connection pipe must be completely sealed, no air leakage, especially welding pipe, welding scar location is particularly easy to ignore.

 

Breakdown drawing