{"id":1097,"date":"2024-06-03T15:28:46","date_gmt":"2024-06-03T07:28:46","guid":{"rendered":"https:\/\/www.tflequip.com\/?post_type=products&#038;p=1097"},"modified":"2024-09-26T14:01:12","modified_gmt":"2024-09-26T06:01:12","slug":"ybx3","status":"publish","type":"products","link":"https:\/\/www.tflequip.com\/de\/products\/ybx3\/","title":{"rendered":"YBX3"},"content":{"rendered":"<h2>Stellen Sie  vor.<\/h2>\n<p class=\"_tgt transPara grammarSection\"><span data-group=\"0-0\" class=\"transSent\"><span>Explosionsgesch\u00fctzter Niederspannungs-Drehstrom-Asynchronmotor der Baureihe YBX3<\/span><\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"1-0\">Rahmennummer: H63-400 <\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"2-0\">Leistung: 0,55~560kW <\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"3-0\">Anzahl der Pole: 2~10P <\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"4-0\">Spannung: 1140 V und darunter <\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"5-0\">Explosionsschutz-Zeichen: Exd lIA T4 Gb, Exd IIB T4 Gb, Exd IIC T4 Gb<\/span><\/p>\n<p>&nbsp;<\/p>\n<h2><strong><b><span>Schwingungseigenschaften von Maschinen mit Ausrichtungsfehlern bei Labor- und Feldversuchen<\/span><\/b><\/strong><\/h2>\n<p>Ziel des Experiments war es, die Art der Vibrationssignatur zu untersuchen, die von der zentral rotierenden Vorrichtung nicht angezeigt wird, sowie den Kraftmechanismus, der zur Erzeugung des Signals beitr\u00e4gt.<\/p>\n<p>Viele, die auf dem Gebiet der Schwingungsanalyse arbeiten, sind der Meinung, dass eine Wellenfehlstellung anhand der folgenden Merkmale erkannt werden kann:<\/p>\n<ol>\n<li><span><\/span>Hochfrequenzkomponente mit der doppelten oder doppelten Betriebsgeschwindigkeit<\/li>\n<li><span><\/span>Hoher axialer Schwingungspegel<\/li>\n<li><span><\/span>180 Grad Phasenunterschied zwischen den beiden Enden der Kupplung<\/li>\n<\/ol>\n<p>Diese Symptome k\u00f6nnen auftreten, wenn sie falsch sind, aber nicht immer. Aus einer Reihe von Versuchen, die mit absichtlich falsch ausgerichteten rotierenden Maschinen durchgef\u00fchrt wurden, und aus vielen Beobachtungen vor Ort an Ger\u00e4ten, die unter falsch ausgerichteten Bedingungen arbeiten, k\u00f6nnen vier Schlussfolgerungen gezogen werden.<\/p>\n<ol>\n<li><span><\/span>Die Schwere der Fehlausrichtung l\u00e4sst sich mit der Schwingungsanalyse nicht feststellen. Mit anderen Worten: Es gibt keinen Zusammenhang zwischen dem Ausma\u00df der Fehlausrichtung und der St\u00e4rke oder Amplitude der Schwingungen.<\/li>\n<li><span><\/span>Unterschiedliche elastische Kupplungskonstruktionen f\u00fchren zu unterschiedlichen Schwingungseigenschaften der dejustierten rotierenden Maschine. Eine falsch ausgerichtete Zahnradkupplung weist zum Beispiel nicht dasselbe Schwingungsmuster auf wie eine falsch ausgerichtete elastische Gummiringkupplung.<\/li>\n<li><span><\/span>Die Schwingungseigenschaften des im Gleitlager gelagerten mechanischen Rotors unterscheiden sich in der Regel von den Schwingungseigenschaften des im W\u00e4lzlager gelagerten mechanischen Rotors.<\/li>\n<li><span><\/span>Die Schwingungscharakteristik der verstellten elastischen Kupplung hat in der Regel ein Vielfaches der Betriebsdrehzahl. Wie bereits erw\u00e4hnt, ist es nur dann sinnvoll, die Phase zu messen, wenn die Hauptschwingung bei der Betriebsdrehzahl auftritt. Wenn der Gro\u00dfteil der Schwingungen bei anderen Frequenzen als der Betriebsdrehzahl auftritt, sind die Phasenwinkeldaten eher bedeutungslos.<\/li>\n<li><span><\/span>Ausrichtungspr\u00fcfung der Kupplung von kleinen rotierenden Ger\u00e4ten im Labor<\/li>\n<li><span><\/span>Zustand der Ausr\u00fcstung:<\/li>\n<\/ol>\n<p>Darunter befindet sich ein Motor mit 1\/2 PS und 1775 U\/min, der eine zentrale Welle mit zwei Ausgleichsplatten antreibt, die mit einer weiteren externen Welle mit einer freitragenden Ausgleichsplatte verbunden ist. Die drei Achsen sind \u00fcber eine flexible Scheibenkupplung miteinander verbunden.<\/p>\n<p>2, Vibrationsmessung:<\/p>\n<p>Das Aggregat wurde fast vollst\u00e4ndig ausgerichtet, mit Betriebsdrehzahl betrieben und die Gesamtschwingungsmessung f\u00fcr alle sechs Lager durchgef\u00fchrt. Dann stoppen, die Schraube l\u00f6sen, die die Zwischenwelle am Rahmen h\u00e4lt, die Zwischenwelle ist seitlich um 31 Millimeter (0,78 mm) versetzt, in dieser Position arretieren, einschalten und die Schwingungen, den Spalt der N\u00e4herungssonde und die Stromst\u00e4rke messen. Schalten Sie die Maschine wieder aus, l\u00f6sen Sie die Schrauben, mit denen die Zwischenwelle am Rahmen befestigt ist, die Zwischenwelle ist um 31mils (0,78mm) zur Seite versetzt (jetzt insgesamt 62mils (1,56mm) zur Seite), arretieren Sie die Position, schalten Sie ein und f\u00fchren Sie eine letzte Vibrationsmessung durch.<\/p>\n<p>3, Vibration, Rotorverformung, Leistungsaufnahme Messergebnisse\uff1a<\/p>\n<p>In fast allen F\u00e4llen nimmt der Vibrationspegel mit zunehmender Versetzung ab. Der Stromverbrauch \u00e4ndert sich von Lauf zu Lauf kaum. Allerdings vergr\u00f6\u00dfert sich der Abstand zwischen der Ann\u00e4herungssonde und der Ausgleichsscheibe fast proportional zum Betrag der Versetzung. Dies beweist, dass die elastische Biegung der Welle tats\u00e4chlich in einer Situation auftritt, die der nachstehenden Abbildung \u00e4hnelt.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171321-300x76.png\" alt=\"\" width=\"300\" height=\"76\" class=\"alignnone size-medium wp-image-1196\" srcset=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171321-300x76.png 300w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171321-768x195.png 768w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171321.png 833w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Zweitens: Feldtest der Schwingungseigenschaften der motorgetriebenen Pumpe unter verschiedenen Ausrichtungsbedingungen<\/p>\n<ol>\n<li><span><\/span>Zustand der Ausr\u00fcstung<\/li>\n<\/ol>\n<p>Die nachstehende Abbildung zeigt einen 60-PS-Motor mit 1775 U\/min und eine Wasserumw\u00e4lzpumpe, die durch eine Metallbandkupplung verbunden sind (siehe Abbildung 2.17), die absichtlich (seitlich) um 21 und 36 mil und vertikal um 55 und 65 mil versetzt ist. Es wurden insgesamt sieben Testl\u00e4ufe unter verschiedenen Ausrichtungsbedingungen durchgef\u00fchrt.<\/p>\n<p>Das bei der Pr\u00fcfung verwendete Schwingungsanalyseger\u00e4t mit einem tragbaren Schwingungsmessger\u00e4t mit Beschleunigungssensor sammelte Schwingungsdaten an f\u00fcnf Punkten jeder Einheit, um den Gesamtmesswert des Lagerkastens aufzuzeichnen. Ein Vibrometer mit magnetischer Basis ist ebenfalls an jeder Sensorposition angebracht, und die Signale werden in den Analysator und den X-Y-Plotter eingespeist, um die Schwingungseigenschaften aufzuzeichnen.<\/p>\n<p>Da das Motorgeh\u00e4use aus Aluminium besteht, wurde eine \u00bc Zoll dicke Kohlenstoffstahlplatte mit Epoxidharz an den horizontalen und vertikalen Seiten der beiden Lager auf den Motor geklebt, und eine weitere Platte wurde an der inneren Endabdeckung angebracht, um die axialen Schwingungspegel zu erfassen.<\/p>\n<p>2, sieben Mal die Kupplung Verlagerung Betrieb<\/p>\n<ul>\n<li><span><\/span>Lauf #1 (Motor abgekoppelt, separater Lauf). Der erste Lauf wird mit abgekoppeltem Motor durchgef\u00fchrt, um festzustellen, ob eine Unwucht des Motors, ein Lagerschaden oder andere Probleme vorliegen, die das Schwingungsverhalten bei Kopplung mit der Pumpe beeintr\u00e4chtigen k\u00f6nnten.<\/li>\n<li><span><\/span>Lauf # 2M2W. Die Pumpe und der Motor sind anfangs innerhalb der zul\u00e4ssigen Ausrichtungstoleranzen gut ausgerichtet.<\/li>\n<li><span><\/span>Lauf # 3M21W. Der Motor befand sich 0,021 Zoll weiter westlich, und w\u00e4hrend des zweiten Laufs wurden keine Ausgleichsscheiben an der Pumpe oder am Motor hinzugef\u00fcgt oder entfernt.<\/li>\n<li><span><\/span>Lauf Nr. 4 M36W (Motor nach Westen 36 mil). Bei diesem Lauf wurde versucht, den Motor weiter nach Westen zu schieben. Der Motor war jedoch mit Bolzen verklemmt und konnte sich nicht weiter zur Seite bewegen.<\/li>\n<li><span><\/span>F\u00fchren Sie #5 M65H (Motorh\u00f6he 65 mil) aus. Der Motor ist jetzt gut von Seite zu Seite positioniert, aber 0,065 Zoll h\u00f6her als die Mittellinie der Pumpenwelle<\/li>\n<li><span><\/span>Lauf #6 M55L (Motor niedrig 55 mil). Bei diesem Testlauf ist die Mittellinie der Motorwelle deutlich niedriger als die Mittellinie der Pumpenwelle, wobei eine gute Links-Rechts-Ausrichtung erhalten bleibt.<\/li>\n<li><span><\/span>F\u00fchren Sie #7 M6W (Motor-6 mils westlich) aus. Richten Sie die Pumpe und den Motor erneut innerhalb akzeptabler Ausrichtungstoleranzen aus (\u00e4hnlich wie beim zweiten M2W-Lauf), um festzustellen, ob sich das Schwingungsverhalten am Lager wiederholt.<\/li>\n<\/ul>\n<p>3, siebenmal laufender Lagerkasten Gesamtschwingungspegel<\/p>\n<p>Die Gesamtschwingungsergebnisse von sieben Testl\u00e4ufen sind in der Abbildung dargestellt. Man beachte, dass bei jedem Trend die Gesamtschwingung nur geringf\u00fcgig zunahm und in einigen F\u00e4llen leicht abnahm, was auf einen Ausrichtungsfehler von 21 und 36 mm zur\u00fcckzuf\u00fchren ist. In einigen F\u00e4llen, wenn sich das Ger\u00e4t im Zustand maximaler Fehlausrichtung (65 mil) befindet, sinkt die Vibration von einem Niveau von 55 mil.<\/p>\n<p>W\u00e4hrend des 7. Laufs war der Gesamtschwingungspegel der Pumpe und des Motors weitgehend derselbe wie beim 2. Lauf, bei dem die Ausrichtungsbedingungen nahezu gleich waren, was best\u00e4tigt, dass die Schwingungen durch Ausrichtungsfehler und andere Faktoren verursacht wurden.<\/p>\n<p>Es gilt: Motor au\u00dfen, Motorkupplungsseite, Wasserpumpenkupplungsseite, Wasserpumpenau\u00dfenlagerschwingung; die horizontale Koordinate ist der Grad der Versetzung der Kupplung<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171506-300x136.png\" alt=\"\" width=\"300\" height=\"136\" class=\"alignnone size-medium wp-image-1197\" srcset=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171506-300x136.png 300w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171506-1024x464.png 1024w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171506-768x348.png 768w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171506.png 1080w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171536-300x133.png\" alt=\"\" width=\"300\" height=\"133\" class=\"alignnone size-medium wp-image-1198\" srcset=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171536-300x133.png 300w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171536-1024x455.png 1024w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171536-768x341.png 768w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171536.png 1080w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171542-300x142.png\" alt=\"\" width=\"300\" height=\"142\" class=\"alignnone size-medium wp-image-1199\" srcset=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171542-300x142.png 300w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171542-1024x485.png 1024w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171542-768x363.png 768w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171542.png 1080w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171548-300x148.png\" alt=\"\" width=\"300\" height=\"148\" class=\"alignnone size-medium wp-image-1200\" srcset=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171548-300x148.png 300w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171548-1024x503.png 1024w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171548-768x378.png 768w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u56fe\u7247_20240624171548.png 1080w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2><strong><b>Wie sind die Installationsverfahren und -prozesse des Pumpenmotors?<\/b><\/strong><\/h2>\n<p>H\u00e4ufige Probleme:<\/p>\n<p>1, die Pumpe Motorleistung Rohr fixiert unvern\u00fcnftig; Der Metallschlauch ist mehr als 80cm lang, und es ist leicht zu rosten, ohne wasserdicht Metallschlauch.<\/p>\n<p>2, die Pumpe Saugrohr Durchmesser Reduktion mit konzentrischen oder exzentrischen Verbindung, leicht zu produzieren Lufts\u00e4cke.<\/p>\n<p>3, Wasserpumpe Einlass und Auslass Rohr zur\u00fcck Bogen, ohne Sto\u00dfd\u00e4mpfung direkt befestigt, keine Sto\u00dfd\u00e4mpfung Ma\u00dfnahmen und nicht f\u00f6rderlich f\u00fcr Rohr Demontage und Installation.<\/p>\n<p>4, die Basis Schraube Installation ist unvern\u00fcnftig. (Flachdichtung, Federblech, Schraube ausgesetzt 1~3 Draht, keine Anti-Korrosions-Ma\u00dfnahmen.)<\/p>\n<p>Allgemeines Verfahren der Pumpenhaustechnik<\/p>\n<p>Wasserpumpenfundament \u2192 Wasserpumpeninstallation \u2192 Rohr- und St\u00fctzinstallation \u2192 Verkabelung und Erdungsinstallation \u2192 Boden und Rinne \u2192 St\u00fctzfu\u00dfende \u2192 Markierung<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" src=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u622a\u56fe_20240624135407-300x212.jpg\" alt=\"\" width=\"300\" height=\"212\" class=\"alignnone size-medium wp-image-1188\" srcset=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u622a\u56fe_20240624135407-300x212.jpg 300w, https:\/\/www.tflequip.com\/wp-content\/uploads\/2024\/06\/\u5fae\u4fe1\u622a\u56fe_20240624135407.jpg 546w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>Technische Spezifikationen f\u00fcr das Pumpenhaus<\/p>\n<p>Anforderungen des Kodex f\u00fcr die Abnahme der Bauqualit\u00e4t der Geb\u00e4udeelektrotechnik:<\/p>\n<p>14.2.10 Die Verlegung von metallischen und nichtmetallischen flexiblen Rohren muss den folgenden Bestimmungen entsprechen:<\/p>\n<ol>\n<li>Die starre Leitung ist \u00fcber die flexible Leitung mit den elektrischen Anlagen und Ger\u00e4ten verbunden, und die L\u00e4nge der flexiblen Leitung betr\u00e4gt nicht mehr als 0,8 m in der Energietechnik und nicht mehr als 1,2 m in der Beleuchtungstechnik.<\/li>\n<li>Die Verbindung zwischen flexiblen Metallrohren oder anderen flexiblen Leitungen und starren Leitungen oder elektrischen Installationen und Ger\u00e4ten wird mit speziellen Verbindern hergestellt; die Verbindungen von flexiblen Metallverbundrohren oder anderen flexiblen Leitungen sind gut abgedichtet, und die fl\u00fcssigkeitsabweisende Deckschicht ist intakt.<\/li>\n<\/ol>\n<p>3, flexible Metallrohr und Metall flexible Rohr kann nicht geerdet werden (PE) oder Null (PEN) durchgehenden Leiter.<\/p>\n<p>\"Anforderungen an den Bau und die Abnahme von Verdichtern, Ventilatoren und Pumpen:<\/p>\n<p>Die L\u00e4nge des geraden Rohrst\u00fccks vor dem Pumpeneinlass sollte nicht weniger als das 3-fache des Einlassdurchmessers D betragen, und die L\u00e4nge des Reduzierrohrs vor und nach der Pumpe sollte nicht weniger als das 5- bis 7-fache des Durchmesserunterschieds der Rohrgr\u00f6\u00dfe betragen; der Einlassdurchmesser der Pumpe nimmt eine exzentrische obere flache Verbindung an, und der Auslass nimmt eine Verbindung mit konzentrischem Durchmesser an.<\/p>\n<p>Anforderungen der \"Bauqualit\u00e4tsnorm f\u00fcr die Wasserversorgung und Entw\u00e4sserung von Geb\u00e4uden und die Heizungstechnik\" :<\/p>\n<p>3.3.15 Die Rohrschnittstelle sollte die folgenden Anforderungen erf\u00fcllen: Der Durchmesser und die L\u00e4nge der Schraube, die den Flansch verbindet, sollte der Norm entsprechen, nach dem Anziehen sollte die L\u00e4nge der \u00fcberstehenden Mutter nicht gr\u00f6\u00dfer als 1\/2 des Schraubendurchmessers sein.<\/p>\n<p>Wichtige Prozesse:<\/p>\n<ol>\n<li>Die Oberfl\u00e4che des Fundaments sollte vor der Installation der Ger\u00e4te gestrichen und poliert werden, um zu verhindern, dass sich der mittlere Teil des Fundaments nach der Installation der Ger\u00e4te schlie\u00dft und dass die Oberfl\u00e4chenschicht des Anstrichs das Schwingungsd\u00e4mpfungspolster der Ger\u00e4te verdeckt.<\/li>\n<li>Die U-PVC-Rinne um das Ger\u00e4t und die Magnetfolie um die Rinne werden zuerst eingegraben, und dann wird die geschliffene Betondeckschicht hergestellt.<\/li>\n<\/ol>\n<p>Installieren Sie das Motorstromrohr auf dem Boden, biegen Sie das Ger\u00e4testromrohr wasserdicht ab, erden Sie die Br\u00fccke zwischen Ger\u00e4t und Stromrohr und schlie\u00dfen Sie die Basisschraube.<\/p>\n<p>Br\u00fccke in den Motor Stromversorgung der Praxis: benutzerdefinierte Kabel f\u00fchren nach unten 45 Grad Design clevere Installation Spezifikationen.<\/p>\n<p>&nbsp;<\/p>\n<h2><strong><b>Merkmale des Pumpenmotors<\/b><\/strong><\/h2>\n<ul>\n<li>Einf\u00fchrung der Pumpenlast<span><\/span><\/li>\n<\/ul>\n<p>Der Spezialmotor f\u00fcr Pumpenlast hat zwei Anwendungsstrukturen, horizontal und vertikal, und weist drei technische Merkmale auf: relativ kleines Anlaufmoment, relativ kleine Anlauffrequenz und relativ lange Dauerlaufzeit.<\/p>\n<p>Normalerweise ist der Pumpenmotor meist ein Asynchronmotor oder ein Synchronmotor mit K\u00e4figl\u00e4ufer, und die Motorleistung ist gr\u00f6\u00dfer als die Wellenleistung einer Klasse, und die Anzahl der Motorpole steht in engem Zusammenhang mit der F\u00f6rderh\u00f6he und dem F\u00f6rderstrom der Pumpe. Wenn die Wellenleistung 22 kW betr\u00e4gt, w\u00e4hlen Sie einen 30 kW-Motor; ein 2-poliger Motor wird im Allgemeinen bei einer etwas gr\u00f6\u00dferen F\u00f6rderh\u00f6he und einem geringen F\u00f6rderstrom verwendet; ein 4-poliger Motor kann bei einem gro\u00dfen F\u00f6rderstrom und einer geringen F\u00f6rderh\u00f6he gew\u00e4hlt werden; w\u00e4hlen Sie einen 4- oder 6-poligen Motor bei einem gro\u00dfen F\u00f6rderstrom und einer geringen F\u00f6rderh\u00f6he.<\/p>\n<ul>\n<li>Anschluss des Pumpenmotors<span><\/span><\/li>\n<\/ul>\n<p>Je nach Anwendungsbereich, Einsatzort und wirtschaftlichen Faktoren usw. gibt es folgende M\u00f6glichkeiten, die Pumpe und den Motor zu verbinden:<\/p>\n<p>1. die Welle der Pumpe ist direkt mit der Motorwelle verbunden;<\/p>\n<p>2. die Welle der Pumpe ist \u00fcber eine Kupplung mit der Motorwelle verbunden;<\/p>\n<p>3. die Welle der Pumpe ist mit der Motorwelle durch das Untersetzungsgetriebe verbunden;<\/p>\n<p>4. die Welle der Pumpe ist mit der Motorwelle durch die Hydraulikkupplung verbunden.<\/p>\n<ul>\n<li><span><\/span>Belastungskennlinie<\/li>\n<\/ul>\n<p>Die Belastung des Pumpenmotors h\u00e4ngt mit der F\u00f6rderh\u00f6he und dem Durchfluss der Pumpe zusammen. Wenn die Pumpe mit hoher F\u00f6rderh\u00f6he an der hohen F\u00f6rderh\u00f6he arbeitet, ist ihr Durchfluss der Durchfluss des Konstruktionspunktes, wenn die niedrige F\u00f6rderh\u00f6he arbeitet, gleichbedeutend mit dem Pumpenauslasswiderstand reduziert wird, dann wird der Durchfluss der Kreiselpumpe steigen, der Pumpenmotor wird \u00fcberlastet, und es wird den Pumpenmotor bis zu einem gewissen Grad verbrennen.<\/p>\n<ul>\n<li>Motor\u00fcberstromschutz<span><\/span><\/li>\n<\/ul>\n<p>Vermeiden Sie einen \u00dcberlastbetrieb des Ger\u00e4ts, so dass die Pumpe lange Zeit mit dem Nennstrom oder \u00dcberstrom betrieben wird. Da der Anlaufstrom des Pumpenmotors das 3-5fache des Nennstroms betr\u00e4gt, sollte besonders darauf geachtet werden, dass das Ger\u00e4t nicht mit Last oder Volllast gestartet wird.<\/p>\n<p>Der Pumpenmotor arbeitet in einer feuchten Arbeitsumgebung. Vor dem Starten des Pumpenmotors sollten die Isolierung der Spule zur Erde und die Isolierung zwischen den Phasen \u00fcberpr\u00fcft werden, und die Wasser- und Feuchtigkeitsbest\u00e4ndigkeit des Pumpenmotors sollte w\u00e4hrend des Betriebs des Pumpenmotors beachtet werden.<\/p>\n<p>Verbesserte Wartung, weniger \u00dcberlastung des Pumpenmotors durch mechanisches Versagen der Pumpe.<\/p>\n<p>\u00dcberwachen Sie die Wicklungstemperatur des Pumpenmotors in Echtzeit, um einen Verbrennungsunfall zu vermeiden, der durch den Ausfall des K\u00fchlsystems verursacht wird. Allgemeine Pumpenmotorspulen sind luftgek\u00fchlt, Tauchpumpen sind wassergek\u00fchlt. Der gro\u00dfe Pumpenmotor wird durch Luft-Luft-W\u00e4rmetauscher und Luft-Wasser-W\u00e4rmetauscher gek\u00fchlt. Wenn das K\u00fchlmedium unterbrochen wird, so dass die Spule die W\u00e4rme nicht ableiten kann, kann die Spule verbrennen.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p>Explosionsgesch\u00fctzter Niederspannungs-Drehstrom-Asynchronmotor der Baureihe YBX3<\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"1-0\">Rahmennummer: H63-400 <\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"2-0\">Leistung: 0,55~560kW <\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"3-0\">Anzahl der Pole: 2~10P <\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"4-0\">Spannung: 1140 V und darunter <\/span><\/p>\n<p class=\"_tgt transPara grammarSection\"><span class=\"transSent\" data-group=\"5-0\">Explosionsschutz-Zeichen: Exd lIA T4 Gb, Exd IIB T4 Gb, Exd IIC T4 Gb<\/span><\/p>","protected":false},"featured_media":1099,"template":"","adweb_product_categories":[115],"adweb_product_tags":[253,121,249,251,252,250,242],"gallery":[1098],"order":null,"acf":[],"_links":{"self":[{"href":"https:\/\/www.tflequip.com\/de\/wp-json\/wp\/v2\/adweb_products\/1097"}],"collection":[{"href":"https:\/\/www.tflequip.com\/de\/wp-json\/wp\/v2\/adweb_products"}],"about":[{"href":"https:\/\/www.tflequip.com\/de\/wp-json\/wp\/v2\/types\/products"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tflequip.com\/de\/wp-json\/wp\/v2\/media\/1099"}],"wp:attachment":[{"href":"https:\/\/www.tflequip.com\/de\/wp-json\/wp\/v2\/media?parent=1097"}],"wp:term":[{"taxonomy":"adweb_product_cat","embeddable":true,"href":"https:\/\/www.tflequip.com\/de\/wp-json\/wp\/v2\/adweb_product_categories?post=1097"},{"taxonomy":"adweb_product_tag","embeddable":true,"href":"https:\/\/www.tflequip.com\/de\/wp-json\/wp\/v2\/adweb_product_tags?post=1097"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}