{"id":1435,"date":"2025-03-13T14:08:33","date_gmt":"2025-03-13T06:08:33","guid":{"rendered":"https:\/\/www.tflequip.com\/?p=1435"},"modified":"2025-03-13T14:08:33","modified_gmt":"2025-03-13T06:08:33","slug":"four-must-know-items-about-the-installation-technology-of-fluorine-lined-centrifugal-pumps","status":"publish","type":"post","link":"https:\/\/www.tflequip.com\/cs\/four-must-know-items-about-the-installation-technology-of-fluorine-lined-centrifugal-pumps\/","title":{"rendered":"\u010cty\u0159i povinn\u00e9 informace o technologii instalace odst\u0159ediv\u00fdch \u010derpadel s fluorovou vlo\u017ekou"},"content":{"rendered":"<p>Odst\u0159ediv\u00e1 \u010derpadla s fluorovou v\u00fdstelkou jsou obecn\u011b odst\u0159ediv\u00e1 \u010derpadla s v\u00fdstelkou z fluoroplast\u016f. Lze je snadno denn\u011b kontrolovat a vym\u011b\u0148ovat uvnit\u0159, ani\u017e by bylo nutn\u00e9 demontovat vstupn\u00ed a v\u00fdstupn\u00ed potrub\u00ed \u010derpadla. P\u0159edpokladem v\u0161ak je, \u017ee proces instalace odst\u0159ediv\u00e9ho \u010derpadla s fluorovou v\u00fdstelkou mus\u00ed pochopit kl\u00ed\u010d k technologii instalace. Zde jsou \u010dty\u0159i polo\u017eky, kter\u00e9 je nutn\u00e9 zn\u00e1t o technologii instalace odst\u0159ediv\u00fdch \u010derpadel s fluorovou vlo\u017ekou a kter\u00e9 v\u00e1m mohou v budoucnu u\u0161et\u0159it spoustu zbyte\u010dn\u00fdch probl\u00e9m\u016f.<\/p>\n<p><img decoding=\"async\" loading=\"lazy\" class=\"size-medium wp-image-1436\" title=\".jpg\" src=\"https:\/\/www.tflequip.com\/wp-content\/uploads\/2025\/03\/-e1741845924898-300x286.jpg\" alt=\".jpg\" width=\"300\" height=\"286\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>1. Kl\u00ed\u010dem k technologii instalace odst\u0159ediv\u00fdch \u010derpadel s fluorovou vlo\u017ekou je ur\u010den\u00ed instala\u010dn\u00ed v\u00fd\u0161ky (tj. sac\u00ed v\u00fd\u0161ky) odst\u0159ediv\u00fdch \u010derpadel s fluorovou vlo\u017ekou. Touto v\u00fd\u0161kou se rozum\u00ed svisl\u00e1 vzd\u00e1lenost od vodn\u00ed hladiny ke st\u0159edov\u00e9 \u010d\u00e1\u0159e ob\u011b\u017en\u00e9ho kola odst\u0159ediv\u00e9ho \u010derpadla s fluorovou vlo\u017ekou. Nelze ji zam\u011b\u0148ovat s p\u0159\u00edpustnou v\u00fd\u0161kou sac\u00edho podtlaku. P\u0159\u00edpustn\u00e1 v\u00fd\u0161ka sac\u00edho podtlaku uveden\u00e1 v n\u00e1vodu k obsluze v\u00fdrobku nebo na v\u00fdrobn\u00edm \u0161t\u00edtku odst\u0159ediv\u00e9ho \u010derpadla s fluorovou vlo\u017ekou se vztahuje k hodnot\u011b podtlaku na vstupn\u00ed \u010d\u00e1sti vody odst\u0159ediv\u00e9ho \u010derpadla s fluorovou vlo\u017ekou a m\u011b\u0159\u00ed se zkou\u0161kou p\u0159i 1 standardn\u00edm atmosf\u00e9rick\u00e9m tlaku a teplot\u011b vody 20 stup\u0148\u016f Celsia. Nezohled\u0148uje podm\u00ednky pr\u016ftoku vody po p\u0159izp\u016fsoben\u00ed sac\u00edho potrub\u00ed. Instala\u010dn\u00ed v\u00fd\u0161ka odst\u0159ediv\u00e9ho \u010derpadla s fluorovou vlo\u017ekou by m\u011bla b\u00fdt zb\u00fdvaj\u00edc\u00ed hodnota po ode\u010dten\u00ed p\u0159\u00edpustn\u00e9 v\u00fd\u0161ky sac\u00edho podtlaku od ztr\u00e1tov\u00e9 v\u00fd\u0161ky sac\u00edho potrub\u00ed vody. Mus\u00ed p\u0159ekonat skute\u010dnou sac\u00ed v\u00fd\u0161ku vody v ter\u00e9nu. Instala\u010dn\u00ed v\u00fd\u0161ka odst\u0159ediv\u00e9ho \u010derpadla s fluorovou vlo\u017ekou nesm\u00ed p\u0159ekro\u010dit vypo\u010dtenou hodnotu, jinak odst\u0159ediv\u00e9 \u010derpadlo s fluorovou vlo\u017ekou nebude schopno \u010derpat vodu.<\/p>\n<p>2. Vliv na vypo\u010dtenou hodnotu m\u00e1 odporov\u00e1 ztr\u00e1tov\u00e1 v\u00fd\u0161ka sac\u00edho potrub\u00ed. Proto se doporu\u010duje p\u0159ijmout co nejkrat\u0161\u00ed uspo\u0159\u00e1d\u00e1n\u00ed potrub\u00ed a instalovat co nejm\u00e9n\u011b kolen a dal\u0161\u00edho p\u0159\u00edslu\u0161enstv\u00ed. Je tak\u00e9 mo\u017en\u00e9 zv\u00e1\u017eit vhodn\u00e9 p\u0159izp\u016fsoben\u00ed vodovodn\u00edho potrub\u00ed o v\u011bt\u0161\u00edm pr\u016fm\u011bru, aby se sn\u00ed\u017eil pr\u016ftok v potrub\u00ed.<\/p>\n<p>3. Je t\u0159eba zd\u016fraznit, \u017ee v p\u0159\u00edpad\u011b chemick\u00fdch \u010derpadel, kdy se nadmo\u0159sk\u00e1 v\u00fd\u0161ka a teplota vody v m\u00edst\u011b instalace odst\u0159ediv\u00e9ho \u010derpadla s fluorovou vlo\u017ekou li\u0161\u00ed od zku\u0161ebn\u00edch podm\u00ednek, jako je m\u00edstn\u00ed nadmo\u0159sk\u00e1 v\u00fd\u0161ka v\u011bt\u0161\u00ed ne\u017e 300 metr\u016f nebo teplota \u010derpan\u00e9 vody p\u0159esahuje 20 stup\u0148\u016f Celsia, je t\u0159eba vypo\u010dtenou hodnotu korigovat. To znamen\u00e1 atmosf\u00e9rick\u00fd tlak v r\u016fzn\u00fdch nadmo\u0159sk\u00fdch v\u00fd\u0161k\u00e1ch a tlak nasycen\u00e9 p\u00e1ry p\u0159i teplot\u011b vody vy\u0161\u0161\u00ed ne\u017e 20 stup\u0148\u016f Celsia. Pokud je v\u0161ak teplota vody ni\u017e\u0161\u00ed ne\u017e 20 stup\u0148\u016f Celsia, lze tlak syt\u00e9 p\u00e1ry zanedbat.<\/p>\n<p>4. Z hlediska technologie instalace potrub\u00ed vy\u017eaduje sac\u00ed potrub\u00ed p\u0159\u00edsn\u00e9 ut\u011bsn\u011bn\u00ed a \u017e\u00e1dn\u00fd \u00fanik vzduchu nebo vody, jinak dojde ke zni\u010den\u00ed podtlaku na vstupu vody do odst\u0159ediv\u00e9ho \u010derpadla s fluorovou vlo\u017ekou, sn\u00ed\u017een\u00ed v\u00fdkonu odst\u0159ediv\u00e9ho \u010derpadla s fluorovou vlo\u017ekou a v z\u00e1va\u017en\u00fdch p\u0159\u00edpadech dokonce k ne\u010derp\u00e1n\u00ed vody. Proto by m\u011bly b\u00fdt pr\u00e1ce na rozhran\u00ed potrub\u00ed prov\u00e1d\u011bny pe\u010dliv\u011b, aby byla zaji\u0161t\u011bna kvalita konstrukce potrubn\u00ed p\u0159\u00edpojky.<\/p>","protected":false},"excerpt":{"rendered":"<p>Fluorine-lined centrifugal pumps are generally centrifugal pumps lined with fluoroplastics. They can be easily inspected and replaced internally on a daily basis without disassembling the pump inlet and outlet pipes. However, the prerequisite is that the installation process of the fluorine-lined centrifugal pump must understand the key to the installation technology. Here are four must-know [&hellip;]<\/p>","protected":false},"author":4,"featured_media":1436,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":[],"categories":[36],"tags":[],"acf":[],"_links":{"self":[{"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/posts\/1435"}],"collection":[{"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/comments?post=1435"}],"version-history":[{"count":0,"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/posts\/1435\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/media\/1436"}],"wp:attachment":[{"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/media?parent=1435"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/categories?post=1435"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.tflequip.com\/cs\/wp-json\/wp\/v2\/tags?post=1435"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}